System 8

Loading...
Shop By
Now Shopping by
  1. nominal flow 1-2 35 l/min Remove This Item
  2. Overall Width 30 mm Remove This Item
  3. Electrical Connection DIN A Remove This Item
Shopping Options
Sheathing material solenoid coil
Average power-on time
1. Kind of Current
leakage max.
Orifice Size Inlet
Orifice Size Exhaust
Orientation of the electr./pneum. Interface
Medium quality according to ISO standard
System affiliation
pneumatic operating mode
Permissible operating temperature max.

System 8

The name “System 8” stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures of all valve components is approximately 8 mm. This value is the major characteristic of this type. The components' efficiency has been increased to the optimum in years of simulation, construction and practical testing.

Application of System 8

The solenoid operators and solenoid valves of system 8 can be used for operating 2/2- or 3/2 way valves, especially in pneumatics.  Available switching functions are normally closed and normally open.

For 3/2 way valves of this series, typical maximum values for operating pressure and nominal orifice are 16 bar/2.5 mm. 2/2 way solenoid operators and solenoid valves can also be used for controlling liquids.

Function

While the solenoid operator/solenoid valve is deenergized, the armature (1) is being pushed down on the lower valve seat (3) by the reset spring (2). The lower valve seat is closed by a sealing element (4). In this switch position the upper valve seat (5) in the magnetic core is open. When the valve is energized, the magnetic force exceeds the force of the reset spring and moves the armature into the opposite extreme position. In this
case the upper valve seat (5) is closed by the sealing element (6), whereas the lower valve seat (3) is open.

Solenoid operators and solenoid valves have identical functionality. However, if solenoid operators are ordered, neither the lower valve seat nor the valve body is shipped.

Those components have to be provided by the customer.

2/2 way valves do not have an upper valve seat. Besides that, the function of the magnet is identical.

Note
We reserve the right to make product changes without notice. For use other than general industrial pneumatics, please consult factory.

Shop By
Now Shopping by
  1. nominal flow 1-2 35 l/min Remove This Item
  2. Overall Width 30 mm Remove This Item
  3. Electrical Connection DIN A Remove This Item
Shopping Options
Sheathing material solenoid coil
Average power-on time
1. Kind of Current
leakage max.
Orifice Size Inlet
Orifice Size Exhaust
Orientation of the electr./pneum. Interface
Medium quality according to ISO standard
System affiliation
pneumatic operating mode
Permissible operating temperature max.

1 Item

Set Descending Direction

Solenoid Valves

Article Number
PriceSystem affiliationType of protectionPower Levelpneumatic operating modeOverall WidthElectrical ConnectionOrientation of the electr./pneum. InterfaceManual OverrideProtective CircuitSheathing material solenoid coil1. Voltage (V)1. Kind of Current1. Power [W]1. power [VA]2. Voltage (V)2. Kind of Current2. Power [W]2. Power [VA]Orifice Size InletOrifice Size ExhaustMin. Operating PressureMax. Operating PressureAverage power-on timePermissible operating temperature min.Permissible operating temperature max.nominal flow 1-2nominal flow 2-3Medium quality according to ISO standardleakage max. Drawing number
Price:System affiliation:

System 8

Type of protection:

Power Level:

pneumatic operating mode:

3/2 NC

Overall Width:

30 mm

Electrical Connection:

DIN A

Orientation of the electr./pneum. Interface:

gegenüberliegend (GÜ)

Manual Override:

Without Manual Override

Protective Circuit:

Sheathing material solenoid coil:

Duroplast

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

4,5 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Orifice Size Inlet:

1,0 mm

Orifice Size Exhaust:

1,3 mm

Min. Operating Pressure:

0,0 bar

Max. Operating Pressure:

10,0 bar

Average power-on time:

15 ms

Permissible operating temperature min.:

-25 °C

Permissible operating temperature max.:

50 °C

nominal flow 1-2:

35 l/min

nominal flow 2-3:

60 l/min

Medium quality according to ISO standard:

3-2-3

leakage max. :

4 ml/min

Drawing number:

per page
Selection:
default

Get a quote