Explosion Protection

Loading...

Explosion Protection

For use in critical (potentially explosive) environments, nass magnet offers components of the System 8 and System 13 series. These are designed according to DIN EN 60079 and tested by the Physikalisch-Technische Bundesanstalt (PTB) according to the European Community Directive 2014/34/EU.


Explosion protection is ensured by using the components specified in the catalog and matched to each other. Furthermore, various country-specific approvals exist, such as the China Compulsory Certification (CCC), a certification system valid China.

System-13-ATEX-Spule---_72N5247-1-small
Shop By
Now Shopping by
  1. 1. Kind of Current DC Remove This Item
  2. System affiliation System 13 Remove This Item
Shopping Options
Type of protection
Electrical Connection
Power Level
Sheathing material
View as Grid Catalog

Items 1-10 of 14

Set Descending Direction

Solenoid Coils

PriceSystem affiliationPower LevelType of protectionOverall WidthElectrical ConnectionSheathing material1. Voltage (V)1. Kind of Current1. Power [W]1. power [VA]2. Voltage (V)2. Kind of Current2. Power [W]2. Power [VA]Voltage Tolerance [%]Voltage Tolerance min. [%]Drawing numberpneumatic operating mode
Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex e

Overall Width:

52 mm

Electrical Connection:

Terminal Box

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

11,7 W

1. power [VA]:

2. Voltage (V):

24 V

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

10,5 VA

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

0519 00.1-00/7149

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

2

Type of protection:

Ex e

Overall Width:

52 mm

Electrical Connection:

Terminal Box

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

4,8 W

1. power [VA]:

2. Voltage (V):

24 V

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

4,3 VA

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

0519 00.1-00/7156

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

12 V

1. Kind of Current:

DC

1. Power [W]:

9,9 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/7215

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

10,1 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/6973

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

12 V

1. Kind of Current:

DC

1. Power [W]:

9,9 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/7006

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

10,1 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/7053

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

10,1 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/7055

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

3

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

10,1 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 00.1-00/7132

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

2

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

24 V

1. Kind of Current:

DC

1. Power [W]:

5,2 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 30.1-00/6974

pneumatic operating mode:

Price:System affiliation:

System 13

Power Level:

2

Type of protection:

Ex m

Overall Width:

36 mm

Electrical Connection:

Cable

Sheathing material:

Thermoplastic

1. Voltage (V):

12 V

1. Kind of Current:

DC

1. Power [W]:

5,1 W

1. power [VA]:

2. Voltage (V):

2. Kind of Current:

2. Power [W]:

2. Power [VA]:

Voltage Tolerance [%]:

10 %

Voltage Tolerance min. [%]:

10 %

Drawing number:

1218 30.1-00/7014

pneumatic operating mode:

Page
per page
Selection:
default

Get a quote